1. The shaking of each axis of the hand wheel is observed. It turns out that there is a problem with the circuit board inside the hand wheel box, and the damaged components can be replaced.
2. The hand wheel is sometimes easy to use and sometimes not easy to use. There is no regularity. It turns out that the resistance inside the hand wheel or the handwheel extension line is too large, and the problem of replacing the spare line is solved.
3. The hand wheel is not sensitive and there is a serious pulse loss. It turns out that the pin at the plug connection is not in place.
4. The hand wheel can't be used. The original plug A/B that is the signal line is X1/X2.
5. The hand wheel can not be used or the hand wheel has a pulse loss phenomenon. It turns out that the cable splitter jump needle is wrong, and should jump between the two sides to stay in the middle.
6. The handwheel cannot be used or the handwheel has a pulse loss phenomenon. The signal cable 6FX2002-4AA21-0xx0 has a broken wire or a virtual connection.
7. The hand wheel can't be used. It turns out that the pulse generator is broken and can only be replaced.